Camesa

Camesa Contact Us - Phone Call us at +1(281) 344-0905,
Camesa Contact Us - Envelope E-mail us, or
Find a Distributor

To access a complete listing of Camesa® wire and wire rope products, please visit: www.CamesaWire.com

Camesa EMC Banner 4

EMC Product Catalog

0.474” (12.04 mm) 3-Conductor Cable 3H47

0.474” (12.04 mm) 3-Conductor Cable 3H47

PROPERTIES:

Cable Diameter: 0.474 +0.005” - 0.002” (12.04 mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 26” (66 cm)
Cable Stretch Coefficient: 0.61 ft/Kft/Klbs (0.69 m/km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,200 VDC
Recommended Operating Conductor Voltage: 500 VDC
Conductor AWG Rating: 18
Minimum Insulation Resistance: 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.1 Ω/Kft (3.6 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 22,000 lbs (97.9 KN) Nominal
Maximum Suggested Working Tension: 11,000 lbs (48.9 KN)
Number and Size of Wires:
Inner Armor 18 x 0.0470” (1.194 mm)
Outer Armor 18 x 0.0655” (1.664 mm)
Average Wire Breaking Strength:
Inner Armor 469 lbs (2.09 KN)
Outer Armor 910 lbs (4.05 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachTape TypeIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
 lbs/Kft
Kg/Km
3H47PP300
149
Poly0.037
0.940
19x0.0100
19x0.254
6.0
19.7
44
144
0.124
3.150
Dacron®369
549
303
451
N/A
3H47PXZ420
216
Camtane0.015
0.381
19x0.0100
19x0.254
6.0
19.7
45
148
0.080
2.032
Dacron®*376
560
310
461
N/A
420
216
ETFE0.022
0.559
19x0.0100
19x0.254
6.0
19.7
45
148
0.124
3.150
Dacron®*376
560
310
461
N/A
3H47PTZ500
260
FEP0.015
0.381
19x0.0100
19x0.254
6.0
19.7
43
141
0.080
2.032
Dacron®*382
568
316
470
N/A
500
260
ETFE0.022
0.559
19x0.0100
19x0.254
6.0
19.7
43
141
0.124
3.150
Dacron®*382
568
316
470
N/A
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
  • Copper strands consist of a total of nineteen wires. Voids in the copper strand are filled with a water-blocking agent. to reduce water and gas migration. Conductor resistance is measured at 68° F.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.

    *Dacron® does not withstand temperatures exceeding 300°F.  Nomex® is available by customer request at time of order for additional cost.