5/16" (8.18 mm) Monoconductor 1N32 Geothermal

5/16" (8.18 mm) Monoconductor 1N32 Geothermal

PROPERTIES:

Cable Diameter: 0.322" +0.005" - 0.002" (8.18mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 18" (45 cm)
Cable Stretch Coefficient: 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 15
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 11,000 lbs (49.0 KN) Nominal
Maximum Suggested Working Tension: 5,500 lbs (24.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0445" (1.130 mm)
Outer Armor 18 x 0.0445" (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 420 lbs (1.87 KN)
Outer Armor 420 lbs (1.87 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N32WG600
316
0.0421
1.067
19x0.0142
19x0.361
3.2
10.5
46
151
0.155
3.937
195
290
161
240
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed. 
  • The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection. 
  • Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. 
  • SUPERSEAL; a special pressure seal agent, is applied between armor layers. 
  • The temperature rating assumes a normal gradient for both temperature and weight. 
  • All values shown are nominal or typical values.