5/16" (8.18 mm) Monoconductor 1N32P Low Resistance, High Strength

5/16" (8.18 mm) Monoconductor 1N32P Low Resistance, High Strength

PROPERTIES:

Cable Diameter: 0.322" +0.005" -0.002 (8.18mm +0.13mm -0.05mm)
Minimum Sheave Diameter: 18" (46 cm)
Cable Stretch Coefficient: 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 13
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @500VDC (457 MegaΩ/Km @500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 12,000 lbs (53.3 KN) Nominal
Maximum Suggested Working Tension: 6,000 lbs (26.6 KN)
Number and Size of Wires:
Inner Armor 12x0.0445" (1.130 mm)
Outer Armor 18x0.0445" (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 442 lbs (1.97 KN)
Outer Armor 442 lbs (1.97 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N32PTZ-LR-HS500
260
FEP0.017
0.432
19x0.0172
19x0.437
2.3
7.5
58
190
0.120
3.048
198
294
163
243
500
260
ETFE0.018
0.444
19x0.0172
19x0.437
2.3
7.5
58
190
0.155
3.937
198
294
163
243

 

  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.