Camesa

Camesa Contact Us - Phone Call us at +1(281) 344-0905,
Camesa Contact Us - Envelope E-mail us, or
Find a Distributor

To access a complete listing of Camesa® wire and wire rope products, please visit: www.CamesaWire.com

Camesa EMC Banner 5

EMC Product Catalog

5/16” (8.26mm) 7-Conductor 7H32

5/16” (8.26mm) 7-Conductor 7H32

PROPERTIES:

Cable Diameter: 0.325” +0.005” - 0.002” (8.26mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 18” (45 cm)
Cable Stretch Coefficient: 1.8 ft/Kft/Klbs (2.02 m/km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1000 VDC
Recommended Operating Conductor Voltage: 500 VDC
Conductor AWG Rating: 22
Minimum Insulation Resistance: 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.3 Ω/Kft (7.5 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 9,500 lbs (42 KN) Nominal
Maximum Suggested Working Tension: 4,750 lbs (21 KN)
Number and Size of Wires:
Inner Armor 18 x 0.0320” (0.81 mm)
Outer Armor 18 x 0.0445” (1.13 mm)
Average Wire Breaking Strength:
Inner Armor 217 lbs (0.97 KN)
Outer Armor 420 lbs (1.87 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachTape TypeIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
 lbs/Kft
Kg/Km
7H32RP300
149
Poly0.013
0.33
7x0.0100
7x0.254
15.8
51.8
55
180
0.056
1.42
Dacron®183
272
152
226
7H32RZ500
260
ETFE0.013
0.33
7x0.0100
7x0.254
15.8
51.8
67
220
0.056
1.42
Dacron®*188
280
157
234
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
  • Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
  • Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68° F.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • Center conductor construction is 7×0.0100”. The typical resistance is reduced by approximately 5 to 10% and the compacitance is increased by approximately 5 to 10% in comparison to the outer conductors.
  • All values shown are nominal or typical values.


*Dacron® does not withstand temperatures exceeding 300°F. Nomex® is available by customer request at time of order for additional cost.


View Product Specification Sheet