7/32” (5.69 mm) Monoconductor 1N22

7/32” (5.69 mm) Monoconductor 1N22

PROPERTIES:

Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 13” (33 cm)
Cable Stretch Coefficient: 2.5 ft/Kft/Klbs (2.81 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,200 VDC
Conductor AWG Rating: 16
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 4.4 Ω/Kft (14.4 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 5,600 lbs (24.9 KN) Nominal
Maximum Suggested Working Tension: 2,800 lbs (12.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 215 lbs (0.96 KN)
Outer Armor 215 lbs (0.96 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N22PP300
149
Poly0.0245
0.622
19x0.0119
19x0.302
4.1
13.5
58
190
0.108
2.743
93
139
77
115
N/A
1N22PXZ420
216
Camtane0.0130
0.330
19x0.0119
19x0.302
4.1
13.5
59
194
0.085
2.159
95
141
80
119
N/A
420
216
ETFE0.0115
0.292
19x0.0119
19x0.302
4.1
13.5
59
194
0.108
2.743
95
141
80
119
N/A
1N22PTZ500
260
FEP0.0130
0.330
19x0.0119
19x0.302
4.1
13.5
58
190
0.085
2.159
96
143
80
119
N/A
500
260
ETFE0.0115
0.292
19x0.0119
19x0.302
4.1
13.5
58
190
0.108
2.743
96
143
80
119
N/A
1N22WG600
316
TE0.0245
0.622
19x0.0119
19x0.302
4.7
15.4
58
190
0.108
2.743
97
144
80
119
N/A
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • The nickel coated copper wires are made of ASTM B355 Class 10 and they are used to increase corrosion protection.
  • Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.