Camesa
Camesa EMC Banner 5

EMC Product Catalog

1/4” (6.55 mm) Monoconductor 1N25-S77 Corrosion Resistant

1/4” (6.55 mm) Monoconductor 1N25-S77 Corrosion Resistant

PROPERTIES:

Cable Diameter: 0.258” +0.005” - 0.002” (6.55mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 14” (36 cm)
Cable Stretch Coefficient: 2.27 ft/Kft/Klbs (2.55 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,200 VDC
Conductor AWG Rating: 16
Minimum Insulation Resistance: 1,500 Mega Ω/Kft @ 500VDC (457 Mega Ω/Km @ 500VDC)
Armor Electrical Resistance: 14.1 Ω/Kft (46.3 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 6,500 lbs (29.8 KN) Nominal
Maximum Suggested Working Tension: 3,250 lbs (14.46 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0358” (0.909 mm)
Outer Armor 18 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 252 lbs (1.12 KN)
Outer Armor 252 lbs (1.12 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N25WA–S77500*
260*
PFA0.032
0.0813
19x0.0119
19x0.302
4.6
15.1
53
174
0.123
3.124
129
191
106
158

* See attached specification sheet for recommended maximum temperature exposure times.

  • While insulation is rated to 1-hour exposure of 500°F, alloy armor wires may have reduced corrosion resistance at temperatures above 400°F.
  • The armor wires are made of corrosion resistant alloy steel suitable for moderate H2S and CO2 environments.
  • Conductor has nickel plated wires adhering to ASTMB355 Class 10 for increased corrosion resistance.
  • Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68°F.
  • Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.


View Product Specification Sheet