Camesa
Camesa EMC Banner 4

EMC Product Catalog

9/32” (7.32 mm) Monoconductor 1N29-EHS Extra High Strength

9/32” (7.32 mm) Monoconductor 1N29-EHS Extra High Strength

PROPERTIES:

Cable Diameter: 0.288” +0.005” - 0.002” (7.32mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 16” (41 cm)
Cable Stretch Coefficient: 1.55 ft/Kft/Klbs (1.74 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 15
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 1000VDC (457 MegaΩ/Km @ 1000VDC)
Armor Electrical Resistance: 2.8 Ω/Kft (9.2 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 10,200 lbs (45.4 KN) Nominal
Maximum Suggested Working Tension: 5,100 lbs (22.7 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0400” (1.016 mm)
Outer Armor 18 x 0.0400” (1.016 mm)
Average Wire Breaking Strength:
Inner Armor 393 lbs (1.75 KN)
Outer Armor 393 lbs (1.75 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N29PTZ– EHS500*
260*
ETFE0.019
0.483
19x0.0142
19x0.361
2.8
9.2
50
180
0.136
3.454
157
234
130
234
500*
260*
FEP0.0135
0.343
19x0.0142
19x0.361
2.8
9.2
50
180
0.098
2.489
157
234
130
193
1N29PP-EHS300*
149*
Poly0.0325
0.826
19x0.0142
19x0.361
2.8
9.2
56
184
0.136
3.454
152
226
126
187
1N29PXZ-EHS420*
216*
Camtane0.0135
0.343
19x0.0142
19x0.361
2.8
9.2
55
184
0.098
2.489
155
230
128
190
420*
216*
ETFE0.019
0.483
19x0.0142
19x0.361
2.8
9.2
55
184
0.136
3.454
155
230
128
190

* See attached specification sheet for recommended maximum temperature exposure times.

  • The armor wires are Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
  • Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • SUPERSEAL, a special pressure seal agent, is applied between armor layers.
  • The temperature rating assumes a normal gradient for both temperature and weight.
  • All values shown are nominal or typical values.


View Product Specification Sheet