Camesa
Camesa EMC Banner 5

EMC Product Catalog

0.355" (9.02 mm) Monoconductor  1Q36-FO

0.355" (9.02 mm) Monoconductor 1Q36-FO

PROPERTIES:

Cable Diameter: 0.355" +0.003" - 0.002" (9.07mm +0.13mm -0.05mm)
Minimum Sheave Diameter: 22" (56 cm)
Cable Stretch Coefficient: 1.0 ft/Kft/Klbs (1.12 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC Central Conductor
Recommended Operating Conductor Voltage: N/A
Conductor AWG Rating: 11
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.99 Ω/Kft (6.53 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 13,100 lbs (58.29 KN) Nominal
Maximum Suggested Working Tension: 6,550 lbs (29.15 KN)
Number and Size of Wires:
Inner Armor 18 x 0.039" (0.991 mm)
Outer Armor 24 x 0.039" (0.991 mm)
Average Wire Breaking Strength:
Inner Armor 357 lbs (1.59 KN)
Outer Armor 357 lbs (1.59 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1Q36YZ-FO500*
260*
ETFE0.032
0.800
14x0.0253
14x0.643
1.26
4.12
139
457
0.208
5.27
228
341
189
282

* See attached specification sheet for recommended maximum temperature exposure times.

  • Number, type and temperature rating of fiber optic elements is dependent on customer request.
  • While insulation is rated to 1-hour exposure of 500°F, the fiber optic element in the cable will dictate the maximum operating temperature for the cable.
  • Fiber in metal tube (FIMT): stainless steel OD of 0.094 in. (2.4 mm). Extra fiber length (EFL) is specified by customer request and subject to manufacturing capabilities.
  • Attenuation increase in the fiber optic under loaded conditions may vary.
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with an anticorrosion compound for protection during shipping and storing. Wires are preformed.
  • Conductor resistance is measured at 68 °F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration
  • .All values shown are nominal or typical values.


View Product Specification Sheet