Camesa
Camesa EMC Banner 5

EMC Product Catalog

5/16" (8.18 mm) Monoconductor  1N32-FO

5/16" (8.18 mm) Monoconductor 1N32-FO

PROPERTIES:

Cable Diameter: 0.322” +0.005” - 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 18” (46 cm)
Cable Stretch Coefficient: 1.2 ft/Kft/Klbs

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 16
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 12,000 lbs (53.4 KN) Nominal
Maximum Suggested Working Tension: 6,000 lbs (24.0 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0445” (1.130 mm)
Outer Armor 18x 0.0445” (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 442 lbs (1.97 KN)
Outer Armor 442 lbs (1.97 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1N32YZ-FO500*
260*
ETFE0.0322
0.818
18x0.0128
18x0.325
3.7
12.13
86
282
0.155
3.937
190
283
157
234

* See attached specification sheet for recommended maximum temperature exposure times.

  • Number, type and temperature rating of fiber optic elements is dependent on customer request.
  • While insulation is rated to 1-hour exposure of 500°F, the fiber optic element in the cable will dictate the maximum operating temperature for the cable.
  • Fiber in metal tube (FIMT): stainless steel OD of 0.065 in. (1.65 mm). Extra fiber length (EFL) is specified by customer request and subject to manufacturing capabilities.
  • Attenuation increase in the fiber optic under loaded conditions may vary.
  • The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with an anticorrosion compound for protection during shipping and storing. Wires are preformed.
  • Conductor resistance is measured at 68 °F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
  • All values shown are nominal or typical values.


View Product Specification Sheet