Camesa
Camesa EMC Banner 4

EMC Product Catalog

0.36" (0.91 mm) Monoconductor  1Q36-FO-S75

0.36" (0.91 mm) Monoconductor 1Q36-FO-S75

PROPERTIES:

Cable Diameter: 0.357" +0.005" -0.002" (9.07mm +0.13mm -0.05mm)
Minimum Sheave Diameter: 22" (56 cm)
Cable Stretch Coefficient: 1.25 Kft/Klbs (1.43 m/Km/5KN)

ELECTRICAL:

Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 11
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 10.4 Ω/Kft (34.1 Ω/Km)

MECHANICAL:

Cable Breaking Strength:
Ends Fixed: 10,200 lbs (45.4 KN) Nominal
Maximum Suggested Working Tension: 5,100 lbs (23.4 KN)
Number and Size of Wires:
Inner Armor 18 x 0.039" (0.991 mm)
Outer Armor 23 x 0.039" (0.991 mm)
Average Wire Breaking Strength:
Inner Armor 286.7 lbs (1.28 KN)
Outer Armor 286.7 lbs (1.28 KN)
Cable TypeCore DescriptionCable Weight
 Temp RatingPlastic TypeInsulation ThicknessCopper ConstructionRes TypicalCap TypicalO.D. EachIn AirIn H2OSpec. Gravity
 °F
°C
 in
mm
in
mm
Ω/Kft
Ω/Km
pf/ft
pf/m
in
mm
lbs/Kft
Kg/Km
1Q36YZ-FO-S75500*
260*
ETFE0.032
0.800
14x0.0253
14x0.643
1.43
4.68
144
472
0.208
5.27
243
361
201
298

* See attached specification sheet for recommended maximum temperature exposure times.

  • Number, type and temperature rating of fiber optic elements is dependent on customer request.
  • While insulation is rated to 1-hour exposure of 500°F, the fiber optic element in the cable will dictate the maximum operating temperature for the cable.
  • Fiber in metal tube (FIMT): stainless steel OD of 0.094 in. (2.4 mm). Extra fiber length (EFL) is specified by customer request and subject to manufacturing capabilities.
  • Attenuation increase in the fiber optic under loaded conditions may vary.
  • While insulation is rated to 1-hour exposure of 500°F, alloy armor wires may have reduced corrosion resistance at temperatures
  • above 350°F.
  • The armor wires are made of corrosion resistant alloy steel suitable for low level H2S and CO2 environments.
  • Conductor has nickel plated wires adhering to ASTMB355 Class 10 for increased corrosion resistance.
  • All values shown are nominal or typical values.


View Product Specification Sheet